| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1006
DC Millivolt Source Model 404S (0.05% Accuracy) |
|
1007
DC Millivolt Potentiometer & Source Model 404N (0.05% Accuracy) |
 |
|
 |
|
Features:
3
ranges up to 1V
0.05%
accuracy
20mA
output current
Short
circuit and overload protection
Portable
with rechargeable batteries.
|
 |
Features:
3
ranges up to 1V
0.05%
accuracy
1
uV null meter resolution
20mA
output current
Short
circuit and overloadprotection
Portable
with rechargeable batteries and carrying case
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1010
DC Voltage Calibrator Model 2003S (0.005% Accuracy) |
|
1017
DC Multi Function VIR Calibrator (0.005% Accuracy) |
|
|
 |
|
Features:
0.01
uV to 10V
0.02%
accuracy
10ppm/hr
stability
20mA
output current
Mains
and battery operation
|
 |
Features:
10nV
- 100V DC Volts
100nA
- 100mA DC Current
10m
Ohms - 10K Ohms Resistance
0.005%
accuracy
Mains/Battery
operation
Portable
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1018
DC Multi Function VIR Calibrator with NULL Measuring (0.005%
Accuracy) |
|
1021
DC Current Source with Null Meter 505N (0.05% Accuracy) |
 |
|
 |
|
Features:
10nV
- 100V DC Volts
100nA
- 100mA DC Current
10m
Ohms - 10K Ohms Resistance
0.005%
accuracy
Mains/Battery
operation Portable
Null
Indicator 1uV max sens
Null
Readout 0 to +/- 0.2V fsd
|
 |
Features:
100mA
output in 3 ranges
0.05%
accuracy
20ppm/hr
stability
1
uV null meter resolution
Up
to 40V output drive
Overload
protection
Portable
with rechargeable batteries and carrying case
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1024
DC Current Calibrator with Null Measuring model 609N |
|
1030
Microcal (Combined Voltage & Current Source) |
 |
|
 |
|
Features:
100mA
output
0.02%
accuracy
10ppm/hr
stability
Null
facility
Mains
and battery operation
Portable
|
 |
Features:
3
voltage ranges to 1V
2
current ranges to 100mA
0.1%
accuracy
Compact
Portable
and battery powered
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1044
DC Voltage and Current Calibrator (0.05% Accuracy) |
|
1045
Calpot (Combined Voltage & Current Calibrator - Potentiometer) |
 |
|
 |
|
Features:
100mA
output
0.02%
accuracy
10ppm/hr
stability
Null
facility
Mains
and battery operation
Portable
|
 |
Features:
3
voltage ranges to 1V
2
current ranges to 100mA
0.1%
accuracy
Compact
Portable
and battery powered
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1047
V-I Loop Calibrator (0.05% Accuracy) |
|
1048
V-I Loop Calibrator (0.02% Accuracy) |
|
|
|
|
Features:
Source
& Measure, both Current & Voltage
3
Current ranges 0 - 22mA
3
Voltage ranges 0 - 22V
Transmitter
Simulator/Sink
Output
Steps and Ramps
Fine
adjustment (Inching)
1047
accuracy 0.05% of span
1048
accuracy 0.02% of span
4.5
digit display
9V
internal battery or mains power
Handheld,
rugged
14
x 8 x 5cm (5.5 x 3 x 2"), 280g (10oz)
|
 |
Features:
Source
& Measure, both Current & Voltage
3
Current ranges 0 - 22mA
3
Voltage ranges 0 - 22V
Transmitter
Simulator/Sink
Output
Steps and Ramps
Fine
adjustment (Inching)
1047
accuracy 0.05% of span
1048
accuracy 0.02% of span
4.5
digit display
9V
internal battery or mains power
Handheld,
rugged
14
x 8 x 5cm (5.5 x 3 x 2"), 280g (10oz)
|
| Simulators/
Calibrators |
|
Simulators/
Calibrators |
| 1077
Millamp Transducer/ Line Simulator (Transim) |
|
1090
Temperature Calibrator |
|
|
|
|
Features:
3 operating modes
100mA
source and load
24
line mode
0.05%
accuracy
Rechargeable
battery cells
Portable
|
 |
Features:
Measure/Simulate
8 thermocouple types, PT100-RTD, mV, and mA
Displays
units in deg C/deg F, uV/mV, or mA
Large
super twist LCD display
Sealed
membrane keypad
Automatic
or manual cold junction compensation
Robust
carrying case with test lead compartment
Inching
and Step functions with configurable step time
Rechargeable
battery power, 24+ hours use
Auto
power-save shutdown
|
| Simulators/
Calibrators |
| 5080
Pat Cal 2 - Calibrator for PAT's and Insulation Testers |
|
|
Calibrator
for PATs and Insulation Testers
Suitable
for traceable calibration of PATs and VDE 0701 testers
Impact resistance case to IEC1010
Battery powered - ensures isolation and prevents inaccuracies
due to stray leakage
Voltage and current displayed on integral LCD digital meter
Safety
interlock prevents contact with Earth Bond studs during
Insulation and Leakage tests
Earth Bond currents up to 50A AC can be accurately measured
Load Test currents up to 13A AC can be accurately measured
|
|
|